TY - JOUR
T1 - Thermal energy performance simulation of a residential building retrofitted with passive design strategies
T2 - A case study in mexico
AU - Vargas, Ana Paola
AU - Hamui, Leon
N1 - Publisher Copyright:
© 2021 by the authors. Licensee MDPI, Basel, Switzerland.
PY - 2021/7/2
Y1 - 2021/7/2
N2 - High energy consumption as a result of an inefficient design has both economic and environmental repercussions throughout the life cycle of a building. In Mexico, the residential sector is the third-largest final energy consumer, therefore improving the performance of existing buildings is considered an effective method in achieving energy savings. Moreover, in Mexico warm climate regions predominate, which impacts energy consumption. This article examines a linked, single-family house located in the hot-humid climate city of Villahermosa, Tabasco (México). DesignBuilder software was used to conduct the thermal energy performance simulation of the existing building (base case) and to evaluate the energy-saving potentials by implementing different passive design strategies. As a result, the annual electricity consumption of the base case decreased a maximum of 2.0% with the passive design strategy in exterior windows, 4.9% in walls and, 13.7% reduction in roofs, the latter being the enclosure with the greatest reduction achieved. Nevertheless, a final adaptation proposal with the passive design strategies, whose results represented the highest energy savings, accomplished a total reduction of 23.5% with a payback period of 5.8 years.
AB - High energy consumption as a result of an inefficient design has both economic and environmental repercussions throughout the life cycle of a building. In Mexico, the residential sector is the third-largest final energy consumer, therefore improving the performance of existing buildings is considered an effective method in achieving energy savings. Moreover, in Mexico warm climate regions predominate, which impacts energy consumption. This article examines a linked, single-family house located in the hot-humid climate city of Villahermosa, Tabasco (México). DesignBuilder software was used to conduct the thermal energy performance simulation of the existing building (base case) and to evaluate the energy-saving potentials by implementing different passive design strategies. As a result, the annual electricity consumption of the base case decreased a maximum of 2.0% with the passive design strategy in exterior windows, 4.9% in walls and, 13.7% reduction in roofs, the latter being the enclosure with the greatest reduction achieved. Nevertheless, a final adaptation proposal with the passive design strategies, whose results represented the highest energy savings, accomplished a total reduction of 23.5% with a payback period of 5.8 years.
KW - Energy efficiency
KW - Hot-humid climate
KW - Passive design strategies
KW - Thermal energy performance simulation
UR - http://www.scopus.com/inward/record.url?scp=85111377738&partnerID=8YFLogxK
U2 - 10.3390/su13148064
DO - 10.3390/su13148064
M3 - Artículo
AN - SCOPUS:85111377738
SN - 2071-1050
VL - 13
JO - Sustainability (Switzerland)
JF - Sustainability (Switzerland)
IS - 14
M1 - 8064
ER -